How can I align deterministic signals?

2 次查看(过去 30 天)
I have some results from a shaking table test that have been carried out.
The input was always the same, however, records where started "by-hand" so they always have different starting times leading to signals that are not aligned. Since I am not an expert in signal processing, I need some help to align them.
I add some example data to this topic to give an idea about the data.

采纳的回答

Star Strider
Star Strider 2023-11-16
Probably the easiest way to do this (with these signals) is simply to threshold the beginning of each to get the index, then use that to adjust the start times for each signal to the same offset.
Try this —
files = dir('*.mat');
for k = 1:numel(files)
LD = load(files(k).name);
fn = fieldnames(LD);
s(k,:) = struct2cell(load(files(k).name, fn{:}));
L(k) = length(s{k});
Fs = 1;
t{k,:} = linspace(0, L(k)-1, L(k))/Fs;
end
figure
hold on
for k = 1:numel(files)
plot(t{k}, s{k})
% ylim([-1 1])
start(k) = find(s{k} > 0.05,1);
end
hold off
grid
[earliest,eidx] = min(start)
earliest = 8221
eidx = 3
figure
tiledlayout(numel(files),1)
for k = 1:numel(files)
nexttile
plot(t{k}, s{k})
grid
xlim([0.75 1.5]*1E+4)
end
sgtitle('Original Signals')
figure
tiledlayout(numel(files),1)
for k = 1:numel(files)
idxrng = start(k) : numel(s{k});
ta{k} = t{k}(1:numel(idxrng)); % Adjusted Time Vector
sa{k} = s{k}(idxrng); % Adjusted Signal Vector
nexttile
plot(ta{k}, sa{k})
grid
end
sgtitle('Time-Adjusted Signals')
.

更多回答(1 个)

Peter Perkins
Peter Perkins 2023-11-16
Some of what SS shows might be easier with timetables:
for i = 1:4
signal = load("ew_data"+i+".mat"); signal = signal.ans;
start = find(abs(signal)>0.05,1,'first');
stop = find(abs(signal)>0.05,1,'last');
tt{i} = timetable(signal(start:stop),RowTimes=seconds(1:(stop-start+1))); % dunno what your time units are
end
ttAll = synchronize(tt{:},"union");
ttAll.Properties.VariableNames = "Signal" + (1:4);
stackedplot(ttAll)
  6 个评论
alegio20
alegio20 2023-11-17
@Star Strider your assumption was correct, and the sampling frequency was the same for every signal: 200 Hz.
alegio20
alegio20 2023-11-17
Thanks for all the great suggestion provided! I will indeed try to use synchronize soon!

请先登录,再进行评论。

类别

Help CenterFile Exchange 中查找有关 Spectral Measurements 的更多信息

产品


版本

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by