unbalanced load on a synchronous generator

7 次查看(过去 30 天)
Hello,
I would like to apply an asymetrical load to a synchronous generator.
The original model has 3ph dynamic AC load as shown below and works perfectly fine.
I would like to apply an asymetrical load now like shown below, I applied a AC dynamic load in Y configuration, each getts a different input
I get wrong results (voltag 2.8e11V for a 400V generator)
Do you have any idea what is wrong?
Is there any possibility to apply an asymetrical load using power preferably (availabe data) and not a current load?
Thank you
reagrds,

回答(1 个)

Joel Van Sickel
Joel Van Sickel 2024-1-3
I tested these blocks and they don't seem to work well when split into a three phase load like this (even for a balanced load). I would recomend using the variable resistor block (there are also variable capacitor and inductor blocks) to implement the asynchronous load. It will require a bit more calculations (converter desired power to desired impedance based on line voltage) but it should give you a path forward to have a controllable load that can also be unbalanced.

类别

Help CenterFile Exchange 中查找有关 Specialized Power Systems 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by