How to connect AUTOSAR client server ports in system composer?
2 次查看(过去 30 天)
显示 更早的评论
It seems that, when creating the AUTOSAR classic architecture with system composer, it is not possible to connect the client server P and R ports of software components which using client server interface to communicate. In the exported arxml files of the software composition, the connectors are also missing for the client server ports.
This is also the same when I create architecture model by importing from existing arxml files of a top level composition authored in external tools(System Desk, or DaVinci Developer), the connectors bewteen client server provide and requested ports are missing.
Has anyone noticed this? It seems to be a serious resitriction for the AUTOSAR supporting tools, since not all AUTOSAR project contains only SR or mode ports. Or anyone has a solution or workaround when building AUTOSAR application architecture?
Thanks alot.
Meng
0 个评论
回答(2 个)
Divyanshu
2024-1-2
编辑:Divyanshu
2024-1-2
Hi Meng,
It is not possible to connect the client and server ports in AUTOSAR classic architecture models. This is actually one of the limitations of 'Creating AUTOSAR Architecture from System Composer Model'.
Please refer the following documentation for further details on other limitations as well:
Hope it helps!
0 个评论
Josh Kahn
2024-3-21
You can use client/server ports in AUTOSAR adaptive. Does that resolve your issue?
Josh
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 AUTOSAR Blockset 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!