Cannot refresh variables when exporting Simulink to FMU file
显示 更早的评论
I am trying to create a simple FMU file from a SimuLink model. I made this many times before. Now, suddenly, I am getting the following error when I try to refresh the settings (using R2024a):
Unable to resolve the name 'internal.getWSLDockerSettings'
I have no idea what that means. A reseach on google resulted in nothing.
I thank for any help.
回答(1 个)
Pooja Kumari
2024-4-25
0 个投票
Hello,
I am also facing the same "Unable to resolve the name 'internal.getWSLDockerSettings'" error when pressing the "Refresh" button, but you can try using the command line API to generate an FMU file.
2 个评论
Wescley Tiago Batista de Sousa
2024-4-25
David
2025-2-12
Hi,
This should work:
open_system('vdp')
set_param('vdp', 'SolverType', 'Fixed-step')
exportToFMU('vdp','FMIVersion','2.0','FMUType','CS')