Running main model with fixed step solver and subsystem with variable step solver

4 次查看(过去 30 天)
My aim is to integrate a Simulink protected model which runs on variable step solver with our vehicle plant model which runs on Fixed step solver ode1 with a time step of 1ms. I would like to know if it is possible to do the same. Any ideas would be appreciated.

采纳的回答

Paul
Paul 2024-4-28
R2022a introduced the concept of a "Local Solver" when using referenced models, which might be what you're looking for. This blog post, and the comments, along with the current, relevant doc pages might be of interest.

更多回答(1 个)

Torsten
Torsten 2024-4-28
移动:Torsten 2024-4-28
Given: Results for both models at time t.
  1. Call the variable step solver for a time period of 1 ms (maybe using the inputs of the fixed step solver at time t).
  2. Call the fixed step solver for a time period of 1 ms (maybe using the inputs of the variable step solver at time t).
  3. Set t = t + 1ms.
  4. Goto 1.
  1 个评论
Paul
Paul 2024-4-28
编辑:Paul 2024-4-29
My initial reaction to this answer was "that's not how Simulink works, at least not easily." But, with R2024a Simulink implemented a new feature called Simulation Objects that may make this approach workable, especially if the protected model and the vehicle plant model only interact with each other at well-defined times. I haven't yet tried Simulation Objects. See this blog post and the doc page(s) linked from there for more information.

请先登录,再进行评论。

类别

Help CenterFile Exchange 中查找有关 Modeling 的更多信息

产品


版本

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by