- PS-Simulink/Simulink-PS Converter block is used to connect a physical signal to simulink ouput signal or vice versa, this cannot be used to connect two different simscape components.
- Now in-order to measure/observe the waveform or input given to 'Two-Level Converter' you might have to use some blocks from 'Simscape>Electrical>Specialized Power Systems>Utilities' like Voltage-Current Simscape Interface (gnd) or Current-Voltage Simscape Interface (gnd).
- Two-level converter once connect to 'Voltage-Current Simscape Interface (gnd)' the other port of this block can be connected to corresponding sensor to measure/observe the input.
What is the port compatibility for Simscape blocks?
4 次查看(过去 30 天)
显示 更早的评论
Hi,
Whenever I work with simscape, I have this issue. Where is the port compatability defined?? I couldnt find any documentation related to this.
Some of the simscpae blocks are not connectable to any other directly in Simulink. Also, the PS-Simulink converter doesnt help
Here(in the fig), you can see that the A port is not connecting to anything. I tried to use all possible ways. My main aim is to connect scope to it and check the waveform. But its not connecting simply. I tried using a voltage sensor, which is a simscape element. But still its not connecting.
Ps: its not the issue of input ports or output ports. The conservative ports ABC in the above image are output ports of the block.
0 个评论
回答(1 个)
Divyanshu
2024-8-1
Hi Raghuveer,
There is no such documentation which has information about port compatibility of all Simscape blocks. Generally, two blocks which belong to different Simscape Components cannot be connected directly.
4 个评论
Divyanshu
2024-8-2
Hi,
I just wanted to direct you towards using the components from same Simscape Paradigm. The blocks which I mentioned earlier are just example which can be used with 'Two-level converter', they may not be required/relevant in your use-case.
Now if you want to observe certain values of 'Two-level converter' on scope block directly:
Here are the measurement blocks which you can directly connect to scope block on one end and other end to 'Two-level converter': 'Current Measurement','Voltage Measurement','Impedance Measurement' etc.
The path to these blocks is: Simscape> Electrical > Specialized Power Systems > Sensors and Measurements.
You may have to choose appropriate block depending upon the use-case.