switching of svpwm is not working . it is not showing staircase mode in scope

1 次查看(过去 30 天)

采纳的回答

Fangjun Jiang
Fangjun Jiang 2024-8-13
编辑:Fangjun Jiang 2024-8-14
To convert radians to degree, the Gain should be 180/pi. You had it as pi/180. That seems to be the cause.
The logic seems correct, although a single Lookup Table block can replace all those blocks, mapping 0~60 to 1, 60~120 to 2, etc.
  1 个评论
PARADESI
PARADESI 2024-8-16
thank you
i have the stair case for the svpwm.
for the three phase grid connected system should i have used the angle from pll and i'm experiencing exponentially increasing waveform. what should i do to settle it down