Inport/Output ordering on subsystem reference in parent model

47 次查看(过去 30 天)
I have a simple subsystem reference model that has 3 inputs and 2 outputs. When referencing the subsystem reference, it was realized that the ports can move within the parent model without affecting the subsystem reference (shown in the image attached). My question is this, is there a way to disallow changing the port order, such that the order would remain in the numbered order of the subsystem reference?

采纳的回答

Swastik Sarkar
Swastik Sarkar 2024-11-11,7:51
Hi @nmb,
I have encountered a situation where ports can be easily rearranged by dragging, as described in the following documentation:
To prevent reordering in the subsystem reference, ports can be locked by marking Subsystem Reference as ReadOnly, a feature introduced in R2021b. More information about this feature is available here:
As shown in the figure, attempts to modify do not allow rearranging the port.

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Subsystems 的更多信息

产品


版本

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by