error in Simulink simulation time

11 次查看(过去 30 天)
I simulate a model in Simulink with a discrete solver, the result of simulation is limited to a reduced interval e6 à10e6 even if I set the simulation time from 0 to 10e6, what is the parameter to change to remedy

回答(2 个)

Sebastian Castro
Sebastian Castro 2015-5-13
1 - Block-dependent settings:
Check if any of your blocks have an explicit sample time that is too small, by going to Display --> Sample Time --> All and looking at the colors/labels.
2 - Global model settings:
Go to your Configuration Parameters (Ctrl+E). In the Solver pane, see if you have set your Max step-size (or if fixed-step, your regular step-size) to this small number.
- Sebastian

studentU
studentU 2015-5-13
Thank's for your replay, i try it but the problem still subsite,
  5 个评论
Sebastian Castro
Sebastian Castro 2015-5-13
If it's the Y-axis, you can just right-click the scope axes and you will get 2 important options:
  1. Axes properties: Lets you manually enter values for Y-min and Y-max, depending on how you want your plot to look.
  2. Autoscale: It will scale the Y-axis automatically to fit all the data
There is also an "Autoscale" button on the scope toolbar. It should look like a square with 4 arrows pointing out at the corners.

请先登录,再进行评论。

类别

Help CenterFile Exchange 中查找有关 General Applications 的更多信息

标签

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by