Hello sir.
I simulated demo model of simpowersystem.
Title is DC/DC and DC/AC PWM Converters
But It's something strange.
In first model Buck-boost converter. The duty is 0.8 in Pulse block properties
But Pulse block output is 0.9 duty ratio. It control half bridge.
Why is it different, If duty is 0.8, Output is 320V
Please check it.
0 个评论
回答(2 个)
Purushottama Rao
2015-5-13
If duty is 0.8, the output was 359V.
If duty is 0.9, the output was 379V. pls see the attached results
2 个评论
Purushottama Rao
2015-5-13
Yeah i do agree with your analysis. There is a mis understanding of the PWM pulse generation. In the model the carrier wave is generated between -1 to 1. By comparing with a constant value of 0.8 or 0.9, the expected output will not be 80% or 90%.
However if you want the duty ratio output as you expect, change the carrier wave to triangular wave between 0 and 1. Pls see the attached.
1 个评论
Purushottama Rao
2015-5-13
Pls note that in this case, the given expression for Vout is not valiD if you change the carrier wave.
Now it will be m*Vin