DC/DC and DC/AC PWM Converters result problem

2 次查看(过去 30 天)
Hello sir.
I simulated demo model of simpowersystem.
Title is DC/DC and DC/AC PWM Converters
But It's something strange.
In first model Buck-boost converter. The duty is 0.8 in Pulse block properties
But Pulse block output is 0.9 duty ratio. It control half bridge.
Why is it different, If duty is 0.8, Output is 320V
Please check it.

回答(2 个)

Purushottama Rao
Purushottama Rao 2015-5-13
If duty is 0.8, the output was 359V.
If duty is 0.9, the output was 379V. pls see the attached results
  2 个评论
Hyounglok Oh
Hyounglok Oh 2015-5-13
Thank you for your analysis.
DId you see PWM wave? Please check duty of PWM wave again. ( Like Below figure )
I checked the model, It set 80% ( Modulation index).
But PWM duty is 90% Final and current average is 160A
then duty modify to 80% the current average is 120A

请先登录,再进行评论。


Purushottama Rao
Purushottama Rao 2015-5-13
Yeah i do agree with your analysis. There is a mis understanding of the PWM pulse generation. In the model the carrier wave is generated between -1 to 1. By comparing with a constant value of 0.8 or 0.9, the expected output will not be 80% or 90%.
However if you want the duty ratio output as you expect, change the carrier wave to triangular wave between 0 and 1. Pls see the attached.
  1 个评论
Purushottama Rao
Purushottama Rao 2015-5-13
Pls note that in this case, the given expression for Vout is not valiD if you change the carrier wave.
Now it will be m*Vin

请先登录,再进行评论。

社区

更多回答在  Power Electronics Control

类别

Help CenterFile Exchange 中查找有关 Power Converters 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by