Some Constant blocks not tunable in Simulink External Mode
5 次查看(过去 30 天)
显示 更早的评论
I'm running 2014a and I am using a Simulink model in External run mode. I have a few constant blocks I'd like to change the value of however they aren't all tunable during run time. For instance, Constant1 and Constant2 are connected to a Subsystem and Constant1's block properties are greyed out during runtime however Constant2's block properties I can change during runtime. They are virtually identically blocks wrt properties. Not sure what's going on here.
3 个评论
Mike Buba
2021-10-24
I noticed the not tunable constants were directly or indirectly, via subtract block (reference - feedback), connected to the PID Controller block.
When I implemented my PI block (similar to as it is under the PID Controller's mask), I could tune them.
回答(1 个)
Sebastian Castro
2015-5-14
Are those constant blocks using hard-coded numerical values or are they variables (either numeric or Simulink.Parameter objects?)
- Sebastian
2 个评论
Sebastian Castro
2015-5-14
Strange... so both "Structure" and "Integrator" are MATLAB structures, then?
Which of those blocks in your screenshot are the constant blocks in question, and what do they feed into?
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Simulink Environment Customization 的更多信息
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!