Problem after Converting the simulink model from R2024a to R2022b

6 次查看(过去 30 天)
I have a Simulink model (1D model using simscape blocks) in R2024a. I have to generate .exe file. Bz of situation, I wanted to degrade my model to R2022b. But when I run that model in R2022b, it causing multiple errors. I have rearranged the simscape blocks there according to R2022b. Even then this error persists. What are the precautions should be taken to eliminate this error?

采纳的回答

Vangala
Vangala 2025-2-11
Hi guys,
Thanks for anwering the question above. I had solved it myself.
In R2022b, When you use pressure and temperature sensor, connect its A to main stream flow and B to the absolute reference. Remove unwanted sensors in the whole loop.
This method solved the issue: "No of variables greater than no. of equations".

更多回答(1 个)

Saurabh
Saurabh 2024-12-11
编辑:Saurabh 2024-12-20
This seems to be a possible bug try running the model using 'sim(bdroot)' and then clicking the hyperlinks which appear in the command window.
I hope this helps

类别

Help CenterFile Exchange 中查找有关 Manual Performance Optimization 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!