How to integrate PCM in battery thermal management system sucessfully ?
4 次查看(过去 30 天)
显示 更早的评论
Objective: Integrate a Phase Change Material (PCM) into the Simulink model EVBatteryCoolingSystem.slx to improve battery thermal management by leveraging latent heat absorption.
Issue: Persistent sscbuild errors ("Cannot find MATLAB namespace 'PCM'") despite:
- Creating a custom PCM component (PCM.ssc) with parameters for melting temperature, latent heat, and mass.
- Organizing folders as +PCM/PCM.ssc (MATLAB package directory).
- Repeated attempts to compile and integrate the PCM block into the Battery subsyste
- Namespace/directory compliance issues during compilation.
- Uncertainty about PCM code syntax or structural errors.
- Difficulty validating PCM behavior in simulations.
- how to resolve namespace errors, validate PCM code/structure, and ensure correct thermal network integration.
3 个评论
Yifeng Tang
2025-7-21
Hi Ali, there isn't any custom .ssc or library associated with what you shared. are you able to share the PCM.ssc file that you mentioned to reproduce the sscbuild errors?