- Check all physical connections are complete, with no unconnected ports. Both electrical and hydraulic networks need proper grounding. Refer to https://www.mathworks.com/help/simscape/ref/electricalreference.html
- Set realistic initial conditions for the motor and pump. Zero or inconsistent values can prevent the system from starting. See https://www.mathworks.com/help/sps/powersys/ug/specifying-initial-conditions.html
- Use a variable-step solver and ensure the simulation time is sufficient. See https://www.mathworks.com/help/simulink/ug/choose-a-solver.html
Simscape – Circuito funziona ma output (portata, potenza, pressione) a zero
2 次查看(过去 30 天)
显示 更早的评论
Ciao a tutti,
sto lavorando in Simscape (Simulink 2025a) su un modello che simula un sistema elettro-idraulico.
Il circuito simula un motore universale che aziona una pompa centrifuga, collegata a una restrizione variabile.
L'obiettivo è osservare:
- La variazione della portata in funzione della restrizione
- Il consumo di potenza elettrica del motore
- La caduta di pressione ai capi della restrizione
Al momento:
- Il modello gira senza errori
- Ma tutti gli output sono fissi a zero
Allego lo schema con i componenti principali:
- Motore Universale alimentato da una sorgente AC
- Pompa idraulica connessa all'albero motore
- Restrizione variabile controllata da un input esterno (slider)
- Sensori di portata, pressione e potenza
Domanda:
Cosa devo impostare o controllare per far sì che:
- La simulazione generi effettivamente flusso/potenza/pressione?
- Si veda la variazione in funzione dell'apertura della restrizione?
Ogni consiglio su come configurare correttamente il blocco del motore, la restrizione o i parametri iniziali è benvenuto!
Grazie in anticipo 🙏
----------
Hi everyone,
I'm working in Simscape (Simulink 2025a) on a model that simulates an electro-hydraulic system.
The circuit represents a universal motor driving a centrifugal pump, which is connected to a variable restriction.My goal is to observe:
- The variation of flow rate as the restriction changes
- The electrical power consumption of the motor
- The pressure drop across the restriction
Current status:
- The model runs without any errors
- However, all outputs remain at zero (Flow = 0, Pressure Drop = 0, Power = 0)
The main components are:
- A Universal Motor powered by an AC source
- A hydraulic pump connected to the motor shaft
- A variable restriction, controlled by an external input (slider)
- Sensors for flow, pressure, and power
My question is:
What should I check or configure to ensure that:
- The simulation actually produces non-zero flow/power/pressure values?
- The system responds properly to changes in the restriction opening?
Any advice on how to correctly set up the motor block, the restriction, or initial conditions is very welcome!
Thanks in advance 🙏
0 个评论
回答(1 个)
Kautuk Raj
2025-7-22
编辑:Kautuk Raj
2025-7-22
To ensure your Simscape electro-hydraulic model produces non-zero outputs and responds to restriction changes, you can try to ensure the following:
0 个评论
另请参阅
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!