simscape current sensor gives arbitrarily large value at t = 0.

3 次查看(过去 30 天)
I am using current sensor block to measure the line current at input of PFC.
The delay block is used to avoid algebraic loops. However the current senor mesures some arbitarily large value of 10^7A,which is not practical. Could it be due to delay block? if yes, how can I avoid it ?

回答(1 个)

Satwik
Satwik 2025-7-23
Hello @Sambeet,
I understand the use of delay block to break algebraic loops in your model. However, when you insert a delay block, on the first simulation step. it outputs its initial condition (zero by default). If the current sensor’s output is used in a feedback loop this initial zero or improper value can cause the calculations to become non-physical, leading to arbitrarily large value.
I recommend trying the following workarounds to resolve this issue:
  • Set the initial condition of the delay block to a realistic value (e.g., the expected initial current at startup). In Simulink, double-click the delay block and set the initial condition parameter.
  • Try using the Memory block instead of the Delay block: https://www.mathworks.com/help/simulink/slref/memory.html
  • Try to restructure the model to avoid algebraic loops altogether, if possible.
I hope this helps!