Control Techniques for PMSM

Currently I'm Taking Control Techniques for PMSM (new), at Current Controller Optimization, Implement MTPA and FWC to optimize your controller. I start taking the task, from 1 to 3 all no issues, but when I take the task 4, and follow the step by step, and checked all the setting are fine, but the output not meet the requirement, checked no error log, please help,

2 个评论

The screenshot is too zoomed out, so it is difficult to identify the exact cause. As a troubleshooting step, remove the current Vector Concatenate block and add a new one with Number of inputs set to 3. Reconnect the signals and check whether the assessment passes.
Signal Assessment appears to be connected to the V_ao output of the PWM Reference Generator. Verify this connection and the block parameters. Use the task’s Hint section to compare the expected setup with your model.
to understand port and connection of PWM, refer to the PWM Reference Generator documentation.
BEN
BEN 2026-10-13,11:24
移动:Torsten 2026-10-13,12:38
Hi Kartikey,
I have reconnected the overall block diagram multiple times and attempted to adjust some of the parameters. However, I am still unable to achieve the correct output. Could you please provide your guidance and advice?
I has captured the connection and parameter for your referance, may help you to do analizing.
Thank you, Ben

请先登录,再进行评论。

回答(2 个)

Kartikey
Kartikey 2026-10-14,12:12

0 个投票

From page 9 of the attached PDF, I noticed a possible angle-unit mismatch. The Input mechanical angle unit parameter of the Mechanical to Electrical Position block is set to Radians, so its electrical-position output is also in radians. However, the Theta units parameter of the SinCos Embedded Optimized block is set to Per-unit.
Could you try changing the Theta units parameter to Radians, rerunning the model, and submitting the task again? I think this may resolve the mismatch. Let me know whether the assessment passes after the change.

1 个评论

Thank you very much, after changed the Theta units parameter of the SinCos Embedded Optimized block from Per-unit to Radians is work.

请先登录,再进行评论。

BEN
BEN about 3 hours 前

0 个投票

Dear Kartikey,
I am working on the assessment that requires adding the SinCos Embedded Optimized block from the Motor Control Blockset. The instructions specify the path as: Motor Control Blockset → Controls → Math Transforms.
However, in my installed version of MATLAB/Simulink, the block only appears under: Motor Control Blockset → Math Transforms (without the 'Controls' folder).
The block itself is present and functions correctly, but the library hierarchy differs. Could you please confirm if using the block from Motor Control Blockset → Math Transforms is acceptable for the assessment, or if a specific version of the toolbox is required?
Thank you for your guidance.
Best regards, Ben

类别

在 帮助中心 和 File Exchange 中查找有关 Control Algorithm Design 的更多信息

提问:

BEN
2026-10-8,13:50

回答:

BEN
2026-10-19,12:43

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!