%<BaseSampleTime> variable not available in simulink model-tlc file?

2 次查看(过去 30 天)
I am trying to create a simulink block that should depend on the base-sample-rate of the model. I tried to put the following in the model-block-tlc file:
%if %<BaseSampleTime> > 0.003
adc1_sum = 0;
for (int i=0; i<8; i++ ) {
adc1_sum += Get_ADC_Value(11);
}
%else
adc1_sum= Get_ADC_Value(11)*8;
%endif
But I get: Undefined identifier BaseSampleTime
Is there a way to determine this value in the models tlc-file? (apart from creating a variable when this value is in scope?)
Thanks in advance, Sietse

采纳的回答

Drew Davis
Drew Davis 2015-6-10
I do not know of any TLC function to get the base sample time of the model. There is however a list of TLC sample time functions that you may find useful. For instance, the function 'LibBlockSampleTime(block)' allows you to access the sample time of the block.

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Target Language Compiler 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by