Can you suggest a way to minimise USB latency using data acquisition tool box with NI6211.

1 次查看(过去 30 天)
I want to try a real time control idea using a NI 6211 DAQ analogue I/O unit through USB. That means single inputs and outputs from within a MatLab loop; I cannot send/receive streams of data. I know the USB will make it pretty slow, but I just want to try out the idea. Can you suggest the best way to minimise the slowness?
  1 个评论
Proact
Proact 2024-6-20
"I've been researching data acquisition units and found your blog really informative!" Proact, founded in 2001 and based in Bengaluru, is a leading force in high-tech industries like aerospace, aviation, electronics, defense, and more. Renowned for innovation and excellence, Proact offers tailored solutions to diverse challenges, making it a trusted partner for businesses. Explore cutting-edge services and products at https://www.proact-ims.com/ or contact us at +91 80 3542 9949 for collaboration and innovation opportunities. Elevate your projects with Proact's expertise.

请先登录,再进行评论。

采纳的回答

Vinod
Vinod 2015-7-13
Try using inputsinglescan and outputsinglescan inside your control loop.
  1 个评论
Jack
Jack 2015-7-23
We've tried that, but we have not got it working. We are using NI C-DAQ 9178 (input module 9234 and output module 9263). Matlab gives the warning: On this platform, notifications more frequent than 20 times per second may not be achievable. Error using Controller1test7 (line 93) The session contains channels that do not support on-demand operations using inputSingleScan and outputSingleScan. Only clocked operations using startForeground and startBackground can be done.
When I met Nick Gautier at Formula Student, he suggested that using the background to receive data and using a new data arrival to trigger a calculation and write the next data point. Attached is the code that fails to do that. Any suggestions?

请先登录,再进行评论。

更多回答(2 个)

Lucien Robinault
Lucien Robinault 2018-1-29
Hello, It will surely be too late for a solution, but have you tried this : https://fr.mathworks.com/help/daq/examples/software-analog-triggered-data-capture.html ?
And to control the data output flow to control in real time you can use the event 'DataRequired' who would trigger a function sending adequat output signal to control your device. https://fr.mathworks.com/help/daq/examples/generate-continuous-and-background-signals-using-ni-devices.html
You can easly see how it's done in the software analog triggered data capture example.

Jens
Jens 2020-6-8
There is a toolbox that seems to replace the Mathworks interface (Matlab DAQ) to the NI driver (NI-DAQmx). Maybe it can help people with a similar problem:
And an illustration of how much faster it is:
  3 个评论
Jens
Jens 2020-6-10
I'm glad you were successful!
I also hear new Matlab versions perform much better for digital in/out over USB. Any experiences with that?

请先登录,再进行评论。