problem while tuning PID controller
显示 更早的评论
I try to tune a PID-Controller in Matlab2010b if i use a discrete one i get the error Message "The second input argument of the "d2d" command must be a positive scalar." if i use a continuous one i get "Input to SVD must not contain NaN or Inf." what i have to pay attention that this block works fine? My system can became NaN due to a Sqrt-expression....
采纳的回答
更多回答(4 个)
Arkadiy Turevskiy
2011-12-12
0 个投票
Can you provide the plant model?
Yoni
2012-1-19
0 个投票
Hi Martin,
I've had the same problem.
It seems the discrete PID option does not handle a sampling time of "-1" (should have inherited the sampling time it that case)
So the workaround for your problem is to enter your own explicit expression for the sampling time. do not leave it on "-1".
This should eliminate the "The second input argument of the "d2d" command must be a positive scalar."
Cheers, Yoni
1 个评论
Nail
2018-5-14
Also, simulation time must not be set to "inf".