I try to tune a PID-Controller in Matlab2010b if i use a discrete one i get the error Message "The second input argument of the "d2d" command must be a positive scalar." if i use a continuous one i get "Input to SVD must not contain NaN or Inf." what i have to pay attention that this block works fine? My system can became NaN due to a Sqrt-expression....
0 个评论
采纳的回答
Arkadiy Turevskiy
2012-2-6
What is the purpose of the memory block that you are using at the output of the PID controller? Long story short, that is what creates the problem.
0 个评论
更多回答(4 个)
Yoni
2012-1-19
Hi Martin,
I've had the same problem.
It seems the discrete PID option does not handle a sampling time of "-1" (should have inherited the sampling time it that case)
So the workaround for your problem is to enter your own explicit expression for the sampling time. do not leave it on "-1".
This should eliminate the "The second input argument of the "d2d" command must be a positive scalar."
Cheers, Yoni