Using a flow coefficient (Cv value) in SymHydraulics
2 次查看(过去 30 天)
显示 更早的评论
Hi all,
currently I want to use SimScape / SimHydraulics to model a system. For several components I have the Cv value (flow coefficient). This is defined as Q = Cv * sqrt(dp*rho_water/rho_liquid) But I cannot find the correct block to implement it. Any suggestions?
Best regards, Luuk
回答(1 个)
Jocie Kluger
2021-8-31
One approach could be to use an Orifice block with area and discharge coefficient parameters. The flow rate equation of this block simplifies to Q= Cd*Area* sqrt(2*dp/rho_liquid). You could adjust the discharge coefficient and Orifice area so Cd*Area*sqrt(2) = Cv*sqrt(rho_water). Here are links to the Orifice blocks in the Isothermal Liquid and Hydraulics libraries:
Alternatively, you could use a Flow Coefficient block in the Thermal Liquid library. Use an Interface (TL-IL) block to interface this block with the Isothermal or Hydraulic network. Don't forget to add a Thermal Liquid properties block to the Flow Coefficient block to specify non-default TL fluid properties.
https://www.mathworks.com/help/physmod/hydro/ref/interfacetlil.html
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Upgrading Hydraulic Models to Use Isothermal Liquid Blocks 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!