DAQ session-based input, is it possible to have different clocks for input and output?
显示 更早的评论
Hello all,
A question for those who have played more with the Session Based interface than I have. I've been updating my DAQ routines that interface with a PCI 6115 to the new, 64-bit version (the old routines gave a noticeable drift for non-zero data). Going through some old data taken with the legacy code I noticed that the input clock was working at 10 MHz and my output clock was at 4 or 2.5 MHz (depending on the number of channels). This is what I want, since these were the rates National Instruments specifies works for analog I/O.
However, with the new session based interface, I'm under the impression that both the input and outputs are tied together clock-wise: If I'm using two output channels the maximum Matlab would let me sample for input is at 2.5 MHz. Is this indeed the case, or is there a way for me to get my input sampling to 10 MHz? And if so, will this be changed in 2012a?
Thank you, Paul
采纳的回答
更多回答(2 个)
Orpheus
2012-5-31
0 个投票
Hi Manisha,
I am in the same situation as Paul, but in my case I am using two different devices on the same chassis. As you mentioned, in addition to a trigger I will also need to share a clock between them. However, I am not sure how to set this up. I would greatly appreciate if you could provide some guidance on this.
I am using the session based interface on Matlab 2012a (64-bit).
Kind Regards, Orpheus
3 个评论
Walter Roberson
2012-5-31
(Orpheus gave more details of devices and rates needed in
http://www.mathworks.com/matlabcentral/answers/40011-assigning-different-sample-rates-in-single-session-session-based-interface )
Orpheus
2012-6-1
Thank you Robert!
Kind Regards,
Orpheus
Feng
2013-8-12
I have a similar problem:
I used one of the counters to trigger an external device and trying to collect data after the trigger. I was able to do it in the legacy DAQ with these codes:
set(ai,'TriggerType','HwDigital')
set(ai,'HwDigitalTriggerSource','PFI0')
set(ai,'TriggerCondition','NegativeEdge')
In session-based DAQ, I have these two lines
s.addTriggerConnection('Dev1/PFI0','Dev1/PFI4','StartTrigger');
s.Connections(1).TriggerCondition = 'FallingEdge';
and it says 'Source and Destination devices can not be the same for a connection'. How should I solve this problem?
Thanks,
Feng
Hakmin
2012-10-15
0 个投票
Hello All,
I don't have any experiences with the session based interface daq. Is it possible to generate multiple analog outputs using a nidaq USB-6259 that are timed differently? I would like to generate an analog signal (30 mins of continuous random noise using appropriate memory buffers) that is presented simultaneously with a shorter 200 ms tone burst that can be triggered independently from the first noise signal. With two session based analogout objects, can I use background trigger events to trigger the two signal types independently?
Thanks for your input
Norman