Manisha

MathWorks

自 2011 起处于活动状态

Followers: 0   Following: 0

消息

统计学

  • 6 Month Streak
  • Revival Level 2
  • Knowledgeable Level 2
  • First Answer

查看徽章

Feeds

排序方式:

已回答
best setup to controlling 8 or more analog outputs
Quickly looking at the supported hardware page for data acquisition toolbox, I see that both NI PCI-6713 and NI 9264 are support...

12 years 前 | 1

已回答
How can I control Timer/Conter input of an NI DAQ Pad-6259 by using the data acquisition toolbox ?
Hi Peter, It seems that your code is correct. I would double check your hardware setup. 1. Is your signal connected to t...

12 years 前 | 0

已回答
Log to .daq with session based API
Hi Birger, The Session-Based Interface currently does not support logging data to a .daq file. However, you can add a callba...

12 years 前 | 0

已回答
Help with addTriggerConnection error?
Hi Jon, What version of MATLAB are you using? And what is the exact error that you get? If you want to manually trigger ...

12 years 前 | 0

| 已接受

已回答
DAQ Toolbox and Calibration
Hi Alan, Currently there is no way to use a saved Measurement and Automation task in MATLAB. Measurement and Automation does...

12 years 前 | 0

已回答
How to create Digtal I/O in Matlab 64-Bit ?
Hi Tobi, Support for non-clocked DIO has been added to the Session-based interface in MATLAB R2012b pre-release. If you have ...

12 years 前 | 0

| 已接受

已回答
external triggering of NI USB-6341with Matlab
Hi Lissa, Counter output channels are not affected by the trigger connection you added in session based interface currently. ...

12 years 前 | 0

已回答
USB 6009 Add Analog Input, Error 200077
Look at this <http://www.mathworks.com/support/bugreports/search_results?search_executed=1&keyword=&release_filter=Exists+in&rel...

12 years 前 | 0

已回答
Data Acquisition from NI PXIe-1062Q
Hi David, It seems that you are using the X- Series device NI PXIe-6358 on the NI PXIe-1062Q PXI chassis. The command |daq.g...

12 years 前 | 4

| 已接受

已回答
multiple Hwdigital triggers to analog output NI device
Hi Hod Dana, If you are using session based interface and MATLAB 2012a, you can use the addTriggerConnection and TriggersPerR...

12 years 前 | 0

已回答
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
Hi Pierre, Is the Coupling property set to the same value ('AC' or 'DC') in both the NI software and the Data Acquisition Too...

12 years 前 | 0

| 已接受

已回答
Possible to retrieve serial number of the DAQ being used?
Hi Mike, You can directly access the NIDAQmx driver functions from DAQ toolbox. [status, serial] = daq.ni.NIDAQmx.DAQm...

12 years 前 | 2

| 已接受

已回答
DAQ with ENET-9163 and NI 9237 National Instruments
Hi Dirk, Support for NI 9237 was added in R2011b. NI 9237 supports only bridge measurements, so if you use R2011b , you shoul...

13 years 前 | 0

已回答
Can't Set 'SingleEnded' TerminalConfig with NI USB-6366 DAQ
If you look at Specification tab of <http://sine.ni.com/nips/cds/view/p/lang/en/nid/209076 USB 6363 datasheet>, you would see th...

13 years 前 | 0

已回答
USING DAQ TOOLBOX TO ACQUIRE MICROPHONE ARRAY DATA USING NI USB 9234
Hi Haritha, NI 9234 has built-in IEPE excitation circuitry. Is your microphone IEPE compliant? If yes, you can use the ne...

13 years 前 | 0

已回答
Onboard device memory overflow. Because of system and/or bus-bandwidth limitations, the driver could not read data from the device fast enough to keep up with the device throughput.
Hi Max, Did you see this <http://www.mathworks.com/support/bugreports/737802 bug report> - Continuous acquisition using sess...

13 years 前 | 1

已回答
The time for adding a channel
Hi Kay, The long time is because of the clear all command you have in the starting. This commands removes all funct...

13 years 前 | 0

已回答
How to improve the time cost of 'putvalue' in DAQ toolbox
Hi Alberich, Have you tried the Session-based interface? 4-5 ms sounds reasonable. Could you explain why you need it to be be...

13 years 前 | 1

已回答
Drive SampleClock to PFI signal as a sanity check.
Hi Adam, If you are uisng Session-based interface, you can use the R2012a prerelease and use the function addClockConnec...

13 years 前 | 0

已回答
Using the DAQ output and calling it as an external function
Hi Mike, It seems that your session object is going out of scope when you call your code as a function from your main script...

13 years 前 | 0

| 已接受

已回答
Data in the Analog Output buffer vanishe before generation
Hi Luc, Any chance you can upgrade to R2011b or R2012a pre-release? With session-based interface, starting 11b, your analog i...

13 years 前 | 0

已回答
DAQ session-based input, is it possible to have different clocks for input and output?
Hi Paul, As you noticed, a session can have only one rate. However, you can always create two sessions- one for your analog i...

13 years 前 | 2

| 已接受

已回答
Simultaneous data acquisiton from two sensors, using the session based interface and serial commands
Hi Kara, There are multiple ways you could achieve this. Option 1. Read the data from your sensor using serial commands ...

13 years 前 | 1

已回答
data aquisition toolbox session based interface -- external clocking of analog input possible?
Hi Eric, Data Acquisition Toolbox MATLAB R2012a prerelease has added new function for triggers and clocks . If you have a val...

13 years 前 | 0

已回答
Session Based Multiple DAQ Triggering
Hi Fernando, DAQ R2012a prerelease has added new functions that you can use to start your acquisition using an external trigg...

13 years 前 | 0

已回答
Repeat outputs with analogoutput without requiering to use putdata repetadly
Hi Micheal, Have you looked at the property <http://www.mathworks.com/help/toolbox/daq/f9-49610.html#f9-33208 TriggerRepeat>?...

13 years 前 | 0

已回答
MATLAB 2010b can not read my DAQ
The prerelease of R2011b Data Acquisition Toolbox supports many non-compactDAQ devices with Session-based interface. If you h...

13 years 前 | 0

已回答
NI DAQ USB 6351 problem on win64 platform
Hi Tomaz, The prerelease of R2011b Data Acquisition Toolbox now supports many non-compactDAQ devices with Session-based inter...

13 years 前 | 2