Problems with Data Aquisition Toolbox 2.17 and National Instruments cDAQ-9172
显示 更早的评论
I use Matlab R2010b and have some problems with data acquisition.
I connected a National Instruments cDAQ-9172 chassis via USB and plugged in a NI-9201 analog input module. To acquire data I used the session-based interface like described in chapter 9 (page 9-8) in the user-guide of the data acquisition toolbox. Everything worked fine.
But then, I wanted to use Matlab Simulink to acquire data. I opened the Data Acquisition block library and added the Analog Input block to my model. When I wanted to specify the block parameters the only device that was shown is my soundcard. Why did not appear the cDAQ-Chassis there?
I installed the NI-DAQmx drivers as well as the "old" traditional drivers (Version 7.3).
采纳的回答
更多回答(1 个)
Walter Roberson
2011-3-8
0 个投票
A card connected through a USB must be doing digital I/O. The Analog Input block is for directly attached A/D cards, I believe.
A device connected via USB has a lot more complications and timing problems and throughput problems than a directly attached device.