Warning message while using camera calibrator

1 次查看(过去 30 天)
I am trying to calibrate a camera using Matlab Camera Calibrator. After I select the images, I am getting the following warning message: "Division by zero when processing. The value has been set to NaN". Any idea why I am getting this warning. Am I suppose to re-size the image?

采纳的回答

Rahul Goel
Rahul Goel 2016-4-12
Hi UNK,
Are you using the images in JPEG format? These warnings look like corrupt exif metadata in the JPEG file that the function is trying to read. This should not affect the actual pixels, so this warning can be ignored. However, please note that saving the calibration images in the JPEG format is not a good idea, because of the compression artifacts. If possible, consider using a format with no compression or with lossless compression, like TIFF or PNG.
Hope this helps.
  2 个评论
UNK
UNK 2016-4-12
Thanks for the information. Just a quick question. Isn't it that the cameras give JPEG images? Am i supposed to convert them to PNG or TIFF images before I use them as the calibration images?
Dima Lisin
Dima Lisin 2016-4-13
There must be a way to set you camera to store uncompressed images.