Matrix is close to singular or badly scaled in SPS
2 次查看(过去 30 天)
显示 更早的评论
Hi, someone knows how to solve this warning in SimpowerSystem? Warning: Matrix is close to singular or badly scaled. Results may be inaccurate. RCOND = 1.521282e-16. Warning: Matrix is close to singular or badly scaled. Results may be inaccurate. RCOND = 1.521282e-16.
1 个评论
采纳的回答
Rohit Kudva
2016-4-14
Hi Tony,
The reason could be that the model is a very stiff system. If it contains a Universal Bridge snubber, you may want to check the compatibility of the time constant of the network and that of the snubber.
To get the stiffness ratio, use the following command:
>> sps=power_analyze(gcs,'detailed'); max(eig(sps.A))/min(eig(sps.A))
-Rohit