I am working on the simulation of a Solid State Transformer.It has three modules- the PWM rectifier, the Dual Active Bridge Converter and the Inverter.The modules work well individually but the input current gets distorted with the whole system.Why??

11 次查看(过去 30 天)
When I am synchronising the PWM Rectifier with the Dual Active Bridge Converter and the Inverter, the current becomes highly distorted. However, the output current and voltage as well as the intermediate stage voltages are perfect as per my design. I have tried several PWM techniques- the abc-dq-abc transform technique, the Direct Power Control technique. However every time it is the input current which gets distorted.

回答(2 个)

Taimur Zaman
Taimur Zaman 2018-5-18
Dear Partha Sarthy, As per my knowledge, your input current is distorting because that you are using very high frequency transformer. Since due to very high switching frequency, the energy residues in the transformer winding, and so a huge current start flowing which means simply shorted. You need to design a good series inductor for your dual active bridge, so that during switching, the energy transfers from transformers to inductor and ZVS phenomeno occur.

Komal Autkar
Komal Autkar 2018-5-18
I am working on MATLAB/simulink model of Solid State Transformer interfaced Wind Energy Conversion System as my post graduate dissertation work. Can anyone send me the simulation model of solid state transformer?
  6 个评论

请先登录,再进行评论。

社区

更多回答在  Power Electronics Control

类别

Help CenterFile Exchange 中查找有关 Specialized Power Systems 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by