Hydraulic circuit between two pressure sources
4 次查看(过去 30 天)
显示 更早的评论
Hello everybody,
I'm new on the community so sorry in advance if my question lacks in suitable formality. I'm a beginner user of Simhydraulics, and I'm modeling a water circuit in which several components (volumes, orefices, local resistances, valves) are linked serially between two hydraulic pressure sources, one higher than the other one. The subsystem "ROTATING VOLUMES" has two variable orefices in parallel that opens together with a certain signal. Apart from geometrical parameters refining, that haven't been set yet, I expect a massic flow from the higher to the lower pressure source. I cannot understand why it keeps being zero. Maybe it's a silly issue but logically it's a nonsense: do you see any glaring error in the model?
Thanks a lot for your time,
Fabio
0 个评论
回答(1 个)
Yifeng Tang
2022-9-14
The pressure sensor you have there blocks the flow totally, lol. It's like voltmeter where no current is let through. Usually the B end of the pressure sensor is connected to a reference block.
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Upgrading Hydraulic Models to Use Isothermal Liquid Blocks 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!