simscapepower and other block connection error
显示 更早的评论
I am trying to create a model using simscape but the unable to make connections between current measurement block to another block. I tried with Simulink ps converter but still having the same problem.For detailed understanding, I attached the image file

回答(1 个)
Andrew Schenk
2016-11-28
0 个投票
You cannot directly interface Simscape Power Systems Specialized Technology blocks with Simscape blocks. Consider replacing the Breaker block with the Simscape block https://www.mathworks.com/help/physmod/sps/ref/singlephasecircuitbreaker.html which will allow a direct connection.
Alternatively, use the following example to show how Specialized Technology blocks can be connected to Simscape blocks: https://www.mathworks.com/help/physmod/sps/powersys/ref/currentvoltagesimscapeinterface.html
类别
在 帮助中心 和 File Exchange 中查找有关 Electrical Sensors 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!