Multiple DAQ Sessions in Background
6 次查看(过去 30 天)
显示 更早的评论
I am aware that acquiring multiple channels with different sampling rates is not currently supported as such. I came across the possible workaround of creating an individual session for each channel and setting those sessions' sampling rate.
This would also allow me to easily control the place where the data should be stored for each channel.
The questions on this are:
- Is is even possible?
- What would that mean for the background acquisition process? In my scenario up to eight channels and therefore eight different sessions would acquire in the background. A listener waits for 3 Mio. datapoint being taken before triggering a storage script, which stores those 3 Mio datapoints into a new file.
- Individual sampling rates are not an absolute must. Is there an easy way to extract data from individual channels?
I am using a NI-PCI 6123 on a Windows 7 machine, MATLAB 2016b. Typical Sampling rates are 100 kHz.
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 National Instruments Frame Grabbers 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!