Problem during installation of support for TI C2000

16 次查看(过去 30 天)
Hello,
I've tried to install the Support for TI C2000 processors. I'm using Matlab R2016a, CCS6.1.3 and ControlSuite v3.4.4. For the installation I used the following support link: https://de.mathworks.com/help/supportpkg/texasinstrumentsc2000/ug/install-support-for-c2000-processors.html?requestedDomain=www.mathworks.com
So first I installed the Embedded Coder Support Package for Texas Instruments C2000 Processors. Then I tried to do the additional Setup Tasks. As toolchain I selected "Texas Instruments Code Composer Studio v6 (C2000)". The following validation of the Code Composer Studio installation worked without any problems, but when I tried to validate the ControlSuite Installation, a error message was displayed which says "Incompatible Texas Instruments Code Composer Studio v6 (C2000) Installation. Expected Version 3.3.9 but found Version 1.2." So I tried to download Version 3.3.9 of the ControlSuite but unfortunately older versions of the ControlSuite are not available from TI. Then I installed the Code Generation Tools 6.4.6 (Before I used Code Generation Tools v15.12.1.LTS) which are proposed in the "Install third-party Software"-window but it didn't help: The Validation of the Code Composer Studio was again successful but not the validation of the ControlSuite Installation.
Does anyone know how to solve this Problem? Thanks in advance for your help!
Soeren
  2 个评论
Milen Krumov
Milen Krumov 2017-1-19
编辑:Milen Krumov 2017-1-19
Hi, Same problem, but i sloved it. Check first line of "<install Dir>\ti\controlSUITE\Release Notes.txt", edit and replace "v 3.4.4 - December 09, 2016" with "v3.4.4 - December 09, 2016"
Soeren
Soeren 2017-1-26
Hi Milen,
thanks for your help! Unfortunately I didn't receive an Email that you commented on my question. So I directly tried the solution proposed by Sumith which also worked :)
Soeren

请先登录,再进行评论。

采纳的回答

Sumith Sekharan
Sumith Sekharan 2017-1-25
Hi,
This was a compatibility issue with latest version of controlSUITE. This is fixed in the latest version (16.1.3) of TI C2000 support package. Hope this helps.
Thanks, Sumith