Simulink variables initializtion problem

2 次查看(过去 30 天)
https://www.mathworks.com/examples/simpower/mw/sps_product-power_PVarray_250kW-250-kw-grid-connected-pv-array
According to this example, all initial variables are defines in power_PVarray_250kW_param.m. It seems that this m files is called at starting simulation. But when I make new simulink file, and even copyed all contents in power_PVarray_250kW.slx, but it doesn't worked.
There are error messages, "Error evaluating parameter 'NominalPower' in 'aaa/120 kV // 25 kV 47 MVA'"
My question is
1. How can I define initial values in simulink using m file 2. Is any options or method to eliminate error messages?
Thanks.

采纳的回答

Hyunsoo Park
Hyunsoo Park 2017-2-6
I found answer;
Menu File -> Model Properties -> Callbacks. In the "PreLoadFcn", you can use a load command. Variables are still stored in MATLAB workspace.

更多回答(1 个)

Ben Rancici
Ben Rancici 2017-2-3
Are you sure that 'NominalPower' is well defined in 'power_PVarray_250kW_param.m'? If so, have you launched this .m file before running the Simulink?
  1 个评论
Hyunsoo Park
Hyunsoo Park 2017-2-3
编辑:Hyunsoo Park 2017-2-3
In case of demonstration file, there is no need to launch m file. I want to automatically launch m file, when simulation starts

请先登录,再进行评论。

类别

Help CenterFile Exchange 中查找有关 Event Functions 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by