How can I change the active variant subsystem before simulation starts?

6 次查看(过去 30 天)
I have a model with multiple instances of a variant subsystem. The variant subsystem itself is in a library. How can I choose which variant to use for each instance using a script? Currently I use the PostLoadFcn callback of my top model to set active variant of each instance using set_param(). But if I edit the variant library block (and I do this often), all instances go back to the default variant in my top model. So I need a way to change them back before I run a simulation, and I don't want to have to close and re-open the top model just to do this (invoking the PostLoadFcn callback).
If I use the InitFcn to set the active variant, I get an error that I can't change variant during simulation.

回答(1 个)

Ankit Bhardwaj
Ankit Bhardwaj 2017-4-26
编辑:Ankit Bhardwaj 2017-4-26
There can be multiple ways to solve this issue.
1. Create an empty subsystem at the top level with an openFcn callback with the same code which you have in postLoadFcn callback. This will be able to fix the variants in one click.
2. You can also think of using Variant objects in the base workspace to fix this issue.
  1 个评论
Max Bjurling
Max Bjurling 2017-4-27
Thanks Ankit! Opening an empty subsystem at top level is certainly easier than closing and reopening the entire model. But I would like to do it all using scripts, and since my model will be simulated by my colleagues too it's a bit unintuitive to have to open and close an empty subsystem. Could you elaborate a bit more on your second suggestion?

请先登录,再进行评论。