The difference of Fundamental Components Switch and normal Switch in SimpowerSystems.

2 次查看(过去 30 天)
I use Matlab 2015a and I want to make ON-off Circuit with Switch module in SimpowerSystems/Simscape components/Switches & Breakers.
But It can't connect with Resister at Simscape/Foundary Library/Electrical Elements. If I change the switch not Switches & Breakers but Foundamental Components's one, It can connect with Resister.
I couldn't understand the difference between these Single-Phase Switches.

采纳的回答

Sebastian Castro
Sebastian Castro 2017-4-25
编辑:Sebastian Castro 2017-4-26
You're using R2015a so you should have the domain-specific line colors.
Many of the Power Systems Simscape Components blocks are light blue, which means that they use the three-phase electrical domain. The Simscape resistor block is a darker blue, meaning it's in the single-phase electrical domain. This is why they won't connect to each other.
You have two options
Sebastian
  1 个评论
Yuji Ito
Yuji Ito 2017-4-26
Thank you for your kind answer. I noticed that the Line colors may different the one,but I conceived my eye are bad so that I might mistake same colors to different colors.
Thank you for your teaching me the meaning of the colors.

请先登录,再进行评论。

更多回答(0 个)