How to optimize active power in VSC-HVDC which is parallel with HVAC line. How can I make objective function and what constraints?
1 次查看(过去 30 天)
显示 更早的评论
I want to optimize the active power in VSC-based HVDC transmission system, which is in parallel to AC line. How can I formulate objective function and constraints?
0 个评论
回答(1 个)
Nakul
2017-5-30
The objective function in the system can be losses. For that you need to account for the converter loss into the model. The constraints can be modulation index /DC link voltage in converter side and AC bus voltage and active power flow in different lines on the AC side.
1 个评论
Arifur Rahman
2017-7-5
编辑:Arifur Rahman
2017-7-5
|I have an objective function for minimizing loss in converter...which is a+b.Ic+c.Ic^2....I have to optimize with linear optimization...Could u help me that what should be constraints for this objective function?
社区
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Problem-Based Optimization Setup 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!