Simscape: Linear transformer open circuit error
8 次查看(过去 30 天)
显示 更早的评论
Hello,
I'm trying to model a full-bridge DC-DC converter in simscape. I have the model built using ideal switches for the mosfets with a simple switching scheme. However, when I run the model, even though the simulation time is 0.05s it comes up with an error that at t=8s, the linear transformer is "open-circuited" because a couple switches are off simultaneously. This off-time should happen and is normal for the switching scheme.
I've attached a couple pictures of my diagram and error.
Would this error be because of no anti-parallel diodes with the switches?
Thanks!
回答(1 个)
Joel Van Sickel
2020-9-2
Hello Ryan,
yes, you can create circuits that our tool cannot simulate with this topology. If you include things like diodes and snubbers, this can solve the problem.
Regards,
Joel
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Simscape Electrical 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!