SINEWAVE IN SCOPE (simscape)
3 次查看(过去 30 天)
显示 更早的评论
Hello, I connected an ac voltage source to a voltage sensor and then trough a ps-to-simulink converter to a scope, in order to see the voltage graph. I use an ode23t solver and the only thing I get is a straight line on the x axis (with value ewual to 0). No sinewave looking voltage/ I set simulation time to 0.1. Why is this happening? Do I need to use different blocks? SCOPE is not appropriate for simscape and physical signals?
Thanks
0 个评论
采纳的回答
Doug Eastman
2012-4-3
To see the sinusoidal voltage variation you need to reduce the step size of the simulation. Go to Simulation -> Configuration Parameters and change the Max step size parameter to be smaller than 1/(2*frequency). For example if the AC frequency is 60 Hz, set the parameter to be 1/120 or 1/240.
1 个评论
K E
2012-4-3
This blog entry may be helpful, http://blogs.mathworks.com/seth/2009/07/14/refining-the-output-of-a-simulation/
更多回答(1 个)
另请参阅
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!