I'm having a problem with using data from an Excel sheet within my example baseline test in Simulink. The test fails with Baseline Criteria Result of "Signal did not align". Can you give me any clue on what might be the problem here. All files in attachment. Thanks.
0 个评论
采纳的回答
Abhishek
2017-11-17
I guess there can be two ways to fix this. Change "Out1" to "Out1:1" in the excel file so that the signal name matches with what the simulation is producing. The other way could be to log the output signal. The root cause is the extra ":1" which gets added for Output ports.