Simscape Power Systems Subsystem

3 次查看(过去 30 天)
Hi all,
I'm trying to condense a Three Phase Inverter into a Subsystem for implementation in a larger model. I was planning on having the input to my Subsystem be the DC Voltage Source and the output be both the bused Three Phase AC Voltage and AC Current Output. I used connection points for the two inputs and just Simulink outs for the Subsystem Outputs.
When I try and run my model, which I assume should work, I get the following errors;
"Goto/From connections cannot cross nonvirtual subsystem boundaries. The only exception is when a goto is
connected to a state output port"
"Invalid connection starts with 'Three_Phase_Inverter_FINAL_Subsystem/DC Voltage Source2/Goto'"
"Invalid connection ends with 'Three_Phase_Inverter_FINAL_Subsystem/Subsystem/powergui/EquivalentModel2/Sources/From1'"
Following the Diagnostic Viewer takes me into the DC Voltage Voltage Source and the Powergui block, but I'm not really sure on the error at all, or why it isn't working like a typical Subsystem.
I'll attach my attempt at creating the Subsystem to create a better picture.
Any help in anyway is much appreciated.
Cheers, Ali.

采纳的回答

Arvind Narayanan
Arvind Narayanan 2017-10-27
移动:Sabin 2022-12-18
The visibility of GoTo block does not cross non-virtual subsystem (i.e. atomic subsystems). You should convert the atomic subsystem to virtual subsystem if you want to pass data using GoTo blocks within the model.

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Switches and Breakers 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by