Consecutive Zero Crossings stop

I'm implementing a Zero-Voltage Switching Buck Converter in SimPowerSystems. It gives me the consecutive zero crossing error. I've disabled that in the Configuration Parameters, but it still stops processing at the same early point. The system is designed to have zero crossings, so I can't just get rid of them.
Is there some way to stop SimPowerSystems from stopping when it hits 1000 zero crossings?

 采纳的回答

Kaustubha Govind
Kaustubha Govind 2012-5-7

2 个投票

You can increase the Number of consecutive zero crossings setting in the Solver pane of the Configuration Parameters window.

更多回答(1 个)

类别

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by