Reset in FilterHDL RTL code

1 次查看(过去 30 天)
Davide Capotosto
Davide Capotosto 2018-1-26
Hello, I would like, when generating RTL code from Filter HDL coder toolbox, to create code with both asynchronous and synchronous resets. Is it possible ? How ? Many thanks in advance

回答(1 个)

Gaurav Phatnani
Gaurav Phatnani 2018-2-2
Hi Davide,
Unfortunately there is no way to generate code for both Asynchronous and Synchronous Reset Types by calling code generation once. In order to do this you will have to run code generation two times.
You can write a MATLAB script to automate this process. This link has some documentation on the Command Line Interface for HDL code generation.
To change the 'ResetType' from a MATLAB script you can use the following function:
>> hdlset_param(gcs,'ResetType','sync') %change the Reset Type to Synchronous
>> hdlset_param(gcs,'ResetType','async') %change the Reset Type to Asynchronous
  1 个评论
Davide Capotosto
Davide Capotosto 2018-2-2
Good afternoon, but if I launch code generation 2 times I will get 2 different codes, one with asynchronous and one with synchronous reset, am I right ? what I was expecting was a method to obtain one piece of code with the 2 reset istantianted. Something like always @(posedge clock or posedge reset_async) begin if (reset_async==1) pdm_data_resampled <=0; else begin if (reset_sync==1) pdm_data_resampled<=0; else begin ..... end
with 2 different codes, the "merge" can be very tedious . Best Regards