Why does the Simulink block mask initialization run twice?

3 次查看(过去 30 天)
If you are debugging a mask initialization, use the keyboard function to stop the code inside the Simulink block mask initialization. You'll notice that the mask is always run twice when a change is made to the mask. Why does the mask run twice?

采纳的回答

Jason Nicholson
Jason Nicholson 2018-3-21
The initialization runs twice if "Icons & Ports"-->"Run initialization" is set to "On" or "Analyze" (assuming MATLAB detects the initialization needs to run). When the initialization runs twice, the order of execution seems to be:
  1. Run "Initialization"
  2. Run "Icons & Ports"
  3. Run "Initialization"

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Simulink Functions 的更多信息

标签

产品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by