three phase fault block
5 次查看(过去 30 天)
显示 更早的评论
How to use external control fault timing?
I have the algorithm to trip the breaker, but how to apply fault using the external control timing, what block that can be connected to it?
0 个评论
采纳的回答
Arnaud Miege
2011-3-24
I assume you are referring to the Three-Phase Fault block from SimPowerSystems. If you look at the documentation for the block, you'll see that it says:
External control of fault timing
If selected, adds a fourth input port to the Three-Phase Fault block for an external control of the switching times of the fault breakers. The switching times are defined by a Simulink signal (0 or 1) connected to the fourth input port of the block.
So the answer is any regular Simulink block, the signal has to be either 0 or 1.
HTH,
Arnaud
0 个评论
更多回答(2 个)
nur izzati
2011-6-9
2 个评论
Arnaud Miege
2011-6-9
Please start a new question rather than add to an existing one. Also, please provide more details: which block are you talking about? what do you mean by polarity? etc... If you have an example model to illustrate your question, even better.