Why my transfer function is irresponsive?

1 次查看(过去 30 天)
Hi, Everyone I have a problem with transfer function application in closed loop buck-boost converter. My transfer function for that converter has higher order in numerator than denominator which is not accepted by the Simulink block. I removed higher order term from the numerator still the transfer function is not responding to the circuit. here is the screenshot of circuit. how to correct the problems. Please advised me. thank you.
  4 个评论
Robert U
Robert U 2018-4-19
Hello Subarna Giri:
The Simulink version you used is newer than mine.
1.) Just applying the transfer function with more zeros than poles means that there is differential behaviour. In real systems there must be a time delay since future values cannot be known. Ergo, the system function has to have at least as much poles as zeros.
2.) Just creating the system function did not cause any troubles in simulink and performed same as expected from step-function. The system response to fast changes in signal is quite slow. You have to check whether response time of your controller fits the fastest relevant change of your system.
Kind regards,
Robert

请先登录,再进行评论。

回答(1 个)

Subarna Giri
Subarna Giri 2018-4-18
Thank you for your kind response. Here is my Simulink model and the screen shot of transfer function. I must use this transfer function. This model has been designed for 12Volt constant output with 5A load. My design is correct in matlab command bode plot but I could not run the model in simulink with there desired parameter. Please help me kindly to solve this problem. Thank you, again. Have a great day.
Regards, Subarna

类别

Help CenterFile Exchange 中查找有关 Event Functions 的更多信息

标签

产品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by