Simscape - how to set outputs from measurement blocks as complex values
4 次查看(过去 30 天)
显示 更早的评论
Hello,
Attached is my simple Simulink (Simscape) model. My question would be: is it possible to get output values from the "Three-Phase V-I Measurement" block as complex numbers? I have set up all the parameters as I thought they should be, but as you can see I still get real values for that block output (Vabc). Am I doing something wrong?
Thanks
0 个评论
回答(1 个)
Joel Van Sickel
2020-9-2
Hello Vanja,
these models do not output complex values, they output the instantaneous actual value at a given time. All three phase's instintaneous values are available, so youc an calculate the complex representation, but the signals should still be maintained as real-scalars inside the simulink model if you want to manipulate them. You can use blocks like this if you want to use complex numbers in simulink: https://www.mathworks.com/help/simulink/slref/realimagtocomplex.html,
Regards,
Joel