Simscape - how to set outputs from measurement blocks as complex values

4 次查看(过去 30 天)
Hello,
Attached is my simple Simulink (Simscape) model. My question would be: is it possible to get output values from the "Three-Phase V-I Measurement" block as complex numbers? I have set up all the parameters as I thought they should be, but as you can see I still get real values for that block output (Vabc). Am I doing something wrong?
Thanks

回答(1 个)

Joel Van Sickel
Joel Van Sickel 2020-9-2
Hello Vanja,
these models do not output complex values, they output the instantaneous actual value at a given time. All three phase's instintaneous values are available, so youc an calculate the complex representation, but the signals should still be maintained as real-scalars inside the simulink model if you want to manipulate them. You can use blocks like this if you want to use complex numbers in simulink: https://www.mathworks.com/help/simulink/slref/realimagtocomplex.html,
Regards,
Joel

类别

Help CenterFile Exchange 中查找有关 Electrical Sensors 的更多信息

产品


版本

R2018a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by