Force update scope window when running rapid accelerator mode from command line

5 次查看(过去 30 天)
As stated in Design Your Model for Effective Acceleration, Simulink does not allow the update of scope unless the rapid accelerator model is run from Simulink menu, for whatever reason. However, I am using a GUI to call the Simulink model and I wish to see real-time output using the scope, but the scopes won't update.
I wonder if there is a way to change this Simulink behaviour (this restriction really seems artificial to me). Alternatively, I wonder if there is a way to pretend (using command line code) that I am running the model from Simulink menu.

采纳的回答

TAB
TAB 2018-10-5
编辑:TAB 2018-10-5
Scope will not update with sim command, but it works with SimulationCommand (please dont ask why :P)
set_param('MyModel', 'SimulationCommand', 'start')
SimulationCommand can take one of following value:
'start' | 'stop' | 'pause' | 'continue' | 'step' | 'update' | 'WriteDataLogs' | 'SimParamDialog' | 'connect' | 'disconnect' | 'WriteExtModeParamVect' | 'AccelBuild'
  3 个评论
TAB
TAB 2018-10-5
You can use get_param('mymodel', 'SimulationStatus') combined with while loop to wait for simulation to finish.
Kaixiang Wang
Kaixiang Wang 2018-10-5
Thanks for your prompt reply. I thought about this but I doubt this is an efficient solution (in the sense that simulation runs slower). I did a few tests and I think this would increase the simulation time by roughly two or three times.
In the end it might be just a design decision to make. The other option is for me to kindly ask the GUI user to hit the Run Simulation button...

请先登录,再进行评论。

更多回答(1 个)

Qiaoli Ji
Qiaoli Ji 2018-12-19
Hi, Kaixiang Wang , I have met a question about matlab compiler installation. So could you help me? Thanks
QQ:1069994175