ADC synchronization with PWM on F2812
2 次查看(过去 30 天)
显示 更早的评论
Hi all,
I set PWM timer mode to be up-down count mode and wonder if I can realize triggering ADC at peak and valley of the PWM timer (basically two samples during one switching period)? When I check the ADC control option in C281x PWM block, it doesn't seem to have the option that I want.
Can anyone give some thought on that? I will be grateful for your help. Thanks.
-Zhe
0 个评论
回答(1 个)
Antonin
2018-11-13
Hi Zhe,
Unfortunately this is not available on the TI F2812 family of chips.
TI added this functionality on newer processors like F28069, F28377S/D, etc.
I suggest that you upgrade to a newer processor if possible.
I hope it helps,
Thanks,
Antonin.