Add dead time in Simulink

234 次查看(过去 30 天)
Hi, I am trying to control an H bridge cell. So in order to avoid two swithes turn ON at the same time, I need to add the dead time. I would expect a similar waveform as below. Does anyone konw how to achieve this in Simulink? Thank you so much!
pwm-complementary-outputs-dead-time.svg

采纳的回答

Rick Hyde
Rick Hyde 2021-11-12
We now have the Gate Driver and Half-Bridge Drive blocks in Simscape™ Electrical™ which allow you to specify dead-time/blanking time in a numerically efficient way. Please see the screenshot below. Hope you find this solution useful.
Rick
  2 个评论
Nueraimaiti Aimaier
Nueraimaiti Aimaier 2022-10-10
Hi,
This is helpful, thanks. However, what kind of ports (or devices) should be connect to the output of Driver? I used Simulink-PS converter for the input, it can be connected. But, at the output, I used PS-Simulink converter and it cannot connected to Simulink signal MOSFET.
Rick Hyde
Rick Hyde 2022-10-17
The output pins of the driver block should be directly connected to Simscape electrical ports on semiconductor device models in the Simscape Electrical library.

请先登录,再进行评论。

更多回答(3 个)

Yonghui Xu
Yonghui Xu 2019-3-28
Add following blocks to your switching signal path and you can set the deadtime by setting the time delay of the transport dealy block.
Dead_Time.JPG

Mark Sherstan
Mark Sherstan 2018-12-14
  5 个评论
Zoe Blatsi
Zoe Blatsi 2020-6-4
Hello,
I tried this for my discrete time PWM model:
and it seems to be working alright:
you could even configure a variable delay in the "delay" block settings.
I hope that helps.
Zoe

请先登录,再进行评论。


Lazuardi Agung
Lazuardi Agung 2022-12-17
thanks, for solving my problem. by just adding transport delay block we can easyly add dead time control