how to solve this problem
6 次查看(过去 30 天)
显示 更早的评论
An error occurred while running the simulation and the simulation was terminated
For block 'PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch', control port value '0' is not in between '1' and '6'. To suppress this message and use the default port, you can change the settings of 'Diagnostic for default case' to 'None'
Component: Simulink | Category: Block error
2 个评论
Walter Roberson
2019-3-4
Either figure out why the control port was 0, or else make the change they suggest.
Sai kartheek Chavali
2019-3-4
PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch
what is the model functionality?
回答(1 个)
Sabin
2025-6-5
Without a model is not possible to point to the root cause but the problem is, as the error points out, the control port of a multiport switch that is 0 but the parameter 'Data port order' is set to One-based contiguous (this means that the out of range condition is: the control input is less than 1 or greater than the number of data inputs.).
0 个评论