how to solve this problem

6 次查看(过去 30 天)
minglangruye bian
回答: Sabin 2025-6-5
An error occurred while running the simulation and the simulation was terminated
For block 'PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch', control port value '0' is not in between '1' and '6'. To suppress this message and use the default port, you can change the settings of 'Diagnostic for default case' to 'None'
Component: Simulink | Category: Block error
  2 个评论
Walter Roberson
Walter Roberson 2019-3-4
Either figure out why the control port was 0, or else make the change they suggest.
Sai kartheek Chavali
PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch
what is the model functionality?

请先登录,再进行评论。

回答(1 个)

Sabin
Sabin 2025-6-5
Without a model is not possible to point to the root cause but the problem is, as the error points out, the control port of a multiport switch that is 0 but the parameter 'Data port order' is set to One-based contiguous (this means that the out of range condition is: the control input is less than 1 or greater than the number of data inputs.).