Simulink Buck Converter Current Mode Control
10 次查看(过去 30 天)
显示 更早的评论
I am trying to simulate a buck converter in Simulink. I want it to be controlled using current mode control. My model does not regulate to the correct voltage and I need some help. Additionally, I am unable to produce coefficients from the PID tuner that allow my system to have a good dynamic load response. (I have a feeling this is becuase there is something wrong with my model.)
My end goal is to use the PID block to tune the system response and then generate code that will then be uploaded to hardware.
1 个评论
Arvind Sathyanarayanan
2019-6-4
编辑:Arvind Sathyanarayanan
2019-6-4
Matthew, you can you save this model in 2017b so I can take a look at it? It can be done by File->Export to previous version.
采纳的回答
Joel Van Sickel
2020-8-18
Hello Matthew,
the first issue is how the PWM is generated. You are using a simulink based PWM generator as well as a simscape based PWM generator. You can delete the simulink based PWM generator and pass your duty cycle directly into the simscape block. You can always test your model with a constant .5 duty cycle to make sure it is doing what you expect before closing the loop. Have you tried that and was it working?
Regards,
Joel
0 个评论
更多回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 PID Controller Tuning 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!