Error in port widths or dimensions.

8 次查看(过去 30 天)
The PI Controller shown in the 1st figure is used in the 2nd figure to simulate a model of PID heat exchanger controller.
ERRORS:
Error in port widths or dimensions. Output port 1 of 'Paper2/Transport Delay HE' is a one dimensional vector with 2 elements.
and
Error in port widths or dimensions. Invalid dimension has been specified for input port 1 of 'Paper2/Heat Exchanger'.
How can I remove these errors?

回答(1 个)

Fangjun Jiang
Fangjun Jiang 2019-7-5
The Outport block "Out1" in "PI Controller" is connected to a BusCreator (or Mux) block. It contains two signals. That might be a mistake. Try to connect "Out1" to the output of block "Control Valve".
  2 个评论
Ananya Singh
Ananya Singh 2019-7-10
Thank you Fangjun Jiang. But the same error is persisting even after connecting "Out1" to the output of block "Control Valve"
Fangjun Jiang
Fangjun Jiang 2019-7-10
All your signals seem to be scalar so the dimension should be 1. Update your model and start from the first place where the dimension shows 2.